a.Develop a Wireless NONEL Initiation System: Create and implement a non
explosive, high-voltage spark ignition system (ESI) that operates wirelessly,
removing the need for manual wiring and retrieval.
b. Enhance Security Features: Add password protection, GPS tracking, and
digital authentication to safeguard against unauthorized access.
c. Improve Operational Efficiency: Allow for the simultaneous initiation of
multiple blast points, which will shorten cycle times and optimize shift usage.
d. Ensure Regulatory Compliance: Design a system that meets DGMS
(Directorate General of Mines Safety) standards and successfully passes safety
and reliability tests for mining use.