RES-URSC-2023-003: Heat pump for heat rejection at elevated temperature
Implementing Organization
Indian Institute of Technology, Palakkad
Principal Investigator
Dr. Vineed Narayanan
Indian Institute of Technology, Palakkad
vineed@iitpkd.ac.in
CO-Principal Investigator
Mr. Tijare
Indian Institute of Technology, Palakkad
Project Overview
The proposed realisation of heat pump system shall use vapour compression cycle. The scope of this project are outlined below:
Source temperature: 0 to 60°C; Heat load at source: 50 to 500 W; Radiator temperature: 100 to 150°C Coefficient of performance: >= 2 (for Evaporator at 45°C and condenser at 100°C).
The heat exchanger in the heat pump unit should be compact and high heat transfer capability heat exchangers that enable effi cient heat absorption from source (generally heat pipe embedded honeycomb panels) and heat rejection to the radiators. Various design approaches shall be explored and rational/ selection criterion shall be evolved.
Achievements
The project being undertaken by ISRO in collaboration with academia is directly or indirectly beneficial to the society.